![Hubner UO-EM-EGS41 Configuration Manual Download Page 15](http://html1.mh-extra.com/html/hubner/uo-em-egs41/uo-em-egs41_configuration-manual_2180884015.webp)
Configuration manual EGS(H)41
15
Changes are made to the settings of the EGS(H)41 on the pages Parameters 1 and Parameters 2. On
the Operating data page you are able to view a collation of all of the device settings and print these
out for documentation purposes.
Online Help
Press 'F1' to display additional information about the individual functions.
4
Parameters 1
On this page the settings are made that define the operating characteristics of the EGS(H)41. You are
able to define the switch-off speeds as well as possible additional speed-dependent functions.
A fundamental condition that applies to all switching speed inputs is that they must be within the de-
vice-specific switching range of 0.5-5400 rpm.
An input value “0” in the field nov_off disables the corresponding switch.
An input value “0” in the field nu-on disabled the underspeed (see chapter 4.2, 4.3).
The speed-dependent functions are displayed in a schematic graphic at the top of the page.
The input fields for entering switching thresholds are displayed in the lower part of the page in table
form. One line is allocated to a respective switch (S1R to S2L).
The columns are allocated to the respective switching thresholds for the speeds nu_on to nov_off and
switch delay.
Depending on the activation boxes selected only those lines and columns are displayed that are rele-
vant to the respective function.
The switches listed in the lines are allocated
as follows
The values listed in the columns are allocated
as follows
S1R:
Switching speeds of switch 1 with
clockwise direction of rotation
nu_off
Switch-off speed for underspeed
detection
S2R:
Switching speeds of switch 2 with
clockwise direction of rotation
nu_on
Switch-on speed for underspeed
detection
S1L:
Switching speeds of switch 1 with
anti-clockwise direction of rotation
nov_off
Switch-off speed for overspeed de-
tection
S2L:
Switching speeds of switch 2 with
anti-clockwise direction of rotation
nov_on
Switch-on speed for overspeed de-
tection
Delay
Delay time applied to triggered
switch-off in ms
Switching range 0,5 … 5400 rpm