![Hubner FG 41 Operating And Assembly Instructions Manual Download Page 35](http://html1.mh-extra.com/html/hubner/fg-41/fg-41_operating-and-assembly-instructions-manual_2180899035.webp)
Incremental Encoder FG 41
35
Permitted cable length
The permissible cable length at the transmission of incremental signals depends on the output
frequency, the applied supply voltage and the ambient temperature of the measuring system,
see the following diagrams.
6.6.1
Analog incremental-signals (SIN/COS)
Fig. 3: Maximum permissible cable length for SIN/COS interface
C
a
b
le
le
n
g
th
in
m
Output frequency in kHz