Parameter

Default Setting

Hook-switch Flash Mode

TBF

DTMF Dial Rate

100:100 ms

Loop-Disconnect Mark-Space Ration

2:1

Loop-Disconnect Interdigit Pause

800 ms

Call Progress Absent Period

0

Call Progress Resume Period

Infinite (255)

Hook-Switch Sensor

Disabled

Dormant State

0

Call-in Trigger

Disabled

Brownout Sensor

Enabled

Dormant State

1

Call-in Trigger

Disabled

RTC Interrupt Sensor

Disabled

Dormant State

1

Call-in Trigger

Disabled

Integrity Loop Sensor

Enabled

Dormant State

0

Call-in Trigger

Disabled

Tilt Sensor

Disabled

Dormant State

0

Call-in Trigger

Disabled

Auxiliary Sensor 1

Disabled

Dormant State

0

Call-in Trigger

Disabled

Auxiliary Sensor 2

Disabled

Dormant State

0

Call-in Trigger

Disabled

Auxiliary Sensor 3

Disabled

Dormant State

0

Call-in Trigger

Disabled

Log Full Fault Detection

Disabled

Call-in Trigger

Disabled

Call-in Failure Fault Detection

Disabled

Call-in Trigger

Disabled

Connection Delay Log

Disabled

Call Log Read Back Rate

100 ms

Emergency Override

Disabled

Summary of Contents for GAI-TRONICS S.M.A.R.T. 293ALSL

Page 1: ...ency Call from a S M A R T Phone 2 Placing a Non Emergency Call Models 294ALSL and 298SL Only 3 Disconnecting a Call Remotely 3 Installation 3 General Safety Guidelines 3 General Installation Guidelin...

Page 2: ...ronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Introduction The GAI Tronics S M A R T Emergency Phones are designed...

Page 3: ...uter and provides access to a wide range of system usage and status reports Refer to the manual provided with the TMS application software for information on available features and for remote programm...

Page 4: ...or wet locations NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modifying telephone lines...

Page 5: ...removing the cover to avoid dropping it 2 Disconnect the front panel from the enclosure 3 Remove the 4 clear spacer rods from the corners of the enclosure and discard 4 Four 0 28 inch holes have been...

Page 6: ...used hole GAI Tronics recommends using silicone sealant around and inside all conduit entries and plugs See Figure 2 for details 6 Pull the telephone line through the conduit Connect the telephone lin...

Page 7: ...Tamper Resistant Screwdriver sold separately 2 Prepare the mounting surface for installation of the back box See Figure 4 for the back box dimensions 3 Install the customer supplied telephone line sur...

Page 8: ...ck remove the cover and connect the green and red wires of the telephone line to the green and the red wires of the modular wall jack See Figure 4 for details Replace the modular wall jack cover 8 Con...

Page 9: ...et to a nominal level that is acceptable for most installations When speaker adjustments are necessary follow these steps 1 Loosen the 4 tamper resistant screws on the front panel using the GAI Tronic...

Page 10: ...ernalPower An external power supply sold separately must be connected to the phone to use the relay output The power supply must provide 200 mA of current 10 V dc to 30 V dc and must be isolated from...

Page 11: ...standard ioms current release 42004 instr manuals 42004 661l2c doc 11 02 ConnectingaBeacon Figure 7 shows a typical connection detail of the GAI Tronics 530A 530FB Beacon and Model C01009 Power Supply...

Page 12: ...a steady pace This is important because the programming sequence times out if there is a pause of more than 2 seconds during the programming sequence Complete the following steps to enter the programm...

Page 13: ...memory location 01 on the EEPROM Auto dial memory storage accommodates up to 24 characters 1 To enter the auto dial number into memory storage or to change the number in storage enter 101 CHAR 1 Data...

Page 14: ...assign a time limit or change an existing time limit 50 Data transfer command 6 999 Call duration 60 9980 seconds 999 disabled See example below End of string indicator Multiply the desired time limit...

Page 15: ...rchase order number If the equipment is under warranty repairs will be made without charge Please include a written explanation of all defects to assist our technicians in their troubleshooting effort...

Page 16: ...State 1 Call in Trigger Disabled RTC Interrupt Sensor Disabled Dormant State 1 Call in Trigger Disabled Integrity Loop Sensor Enabled Dormant State 0 Call in Trigger Disabled Tilt Sensor Disabled Dorm...

Page 17: ...93SL Construction Valox safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203 2 101 6 mm Weight 4 0 lbs Model 293ALSL Construction Cast aluminum painted safety yellow Dimensions 9 5 H 8 W 4 D inches...

Reviews: