Procedure
Step 1
Perform a pre-replacement check.
Check whether there is a redundant fan module and whether the Running/Alarm indicator of
the fan module is steady green, as shown in
. For details about the indicators on
different components, see
Running/Alarm Indicators on a Dorado6000 V3 Controller
Figure 4-51
Running/Alarm indicator on a fan module
You can perform replacement only when a redundant fan module exists and the redundant fan
module is working properly.
Step 2
Wear an ESD wrist strap.
Step 3
Remove a fan module, as shown in
1.
Press the latch on the panel to open the panel.
2.
Press the latches on the fan module to pull out the fan module.
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
50