ViewPoint 8650C
User Guide
6 Holding a Conference on the Web Interface
Issue 10 (2013-07-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
62
Table 6-2
Component data plan
Component
IP Address
Other Configuration
8650C
200.54.0.144
None
GK
200.54.0.144
NOTE
Use the embedded GK of
the 8650C.
None
HUAWEI ViewPoint
9000 HD
videoconferencing
endpoint 1
200.54.10.137
Site name: site1
GK address: 200.54.0.144
Site number: 0100001
GK authentication name:
terminal1
HUAWEI ViewPoint
9000 HD
videoconferencing
endpoint 2
200.54.10.138
Site name: site2
GK address: 200.54.0.144
Site number: 0100002
GK authentication name:
terminal2
Setting GK
The GK functions as a bridge to transfer call information between videoconferencing
endpoints and the MCU, translates the addresses of the videoconferencing endpoints and the
MCU, and controls calls and bandwidth. The 8650C supports Built-In GK, you can set the
Built-In GK enabled and registers 8650C with it.
Step 1
Enable Built-In GK.
1.
Log in to the MCU web interface.
2.
Choose
Gatekeeper
>
Settings
.
3.
Select
Enable Built-In Gatekeeper
and set
GK ID
to
GK1
.
Remain other parameters the default values.
4.
Click
OK
.
Step 2
Register with GK.
1.
Log in to the MCU web interface.
2.
Choose
Settings
>
H.323 and SIP
>
Gatekeeper
.
3.
Set GK parameters listed in
and other parameters to the default values.
Table 6-3
Gatekeeper parameters
Parameter
Description
Setting
Register with
Gatekeeper
Whether the MCU registers with a GK.
Selected: The MCU registers with a GK. After the
Select this
option.