Figure 7-14 Time-of-use
Table 7-3 Description of battery control parameters
Parameter
Description
Value Range
Control mode
● If this parameter is set
to Fixed charge/
discharge, the battery
is charging or
discharging during
the configured period.
A maximum of 10
time periods can be
added.
● If this parameter is set
to Maximum self-
consumption and the
SUN2000 is connected
to a smart power
sensor, the SUN2000
provides output
power for local loads
before feeding the
remaining power to
the power grid.
● If this parameter is set
to Time-of-use, the
battery is discharged
when the electricity
price is high and
charged when the
electricity price is low.
A maximum of 10
time periods can be
added.
● Fixed charge/
discharge
● Maximum self-
consumption
● Time-of-use
----End