SmartACU2000D Smart Array Controller
User Manual (with No PID Module)
2 Overview
Issue 01 (2020-02-14)
Copyright © Huawei Technologies Co., Ltd.
16
Figure 2-8
SmartACU2000D-D-00 and SmartACU2000D-D-05CN Components
Table 2-3
Components and reserved installation positions
No.
Name
Specifications
Quantity
1
Power adapter of the
SmartLogger (U01)
AC input: 100–240 V, 50 Hz/60 Hz
DC output: 12 V/2 A
1
2
Position for the 24 V DC
power module (U02)
AC input: 100–240 V, 50 Hz/60 Hz
DC output: 12 V DC, 60 W (maximum); 24 V
DC, 30 W (maximum)
NOTE
If an external 24–28 V DC input is used, the DC
output voltage ranges from 21.5 V to 25.2 V.
The 24 V DC power module is optional. Its
installation position is reserved in the cabinet.
1
3
AC input terminal of the 24
V power module (JX02)
220 V/2P
1
4
Single-phase surge protective
device (SPD) (F03)
U
c
= 385 V AC; 20 kA/40 kA; 8/20 μs; 4P
1
5
Three-phase SPD (F01)
U
c
= 680 V AC; 20 kA/40 kA; 8/20 μs; 1P
4