![Huawei S6700 Series Configuration Manual Download Page 276](http://html.mh-extra.com/html/huawei/s6700-series/s6700-series_configuration-manual_169517276.webp)
NOTE
It is recommended to adjust the difference between the LSP refresh period and the maximum
Keepalive time of the LSP depending on the network scale.
l
Configuring the Max Lifetime of an LSP
1.
Run:
system-view
The system view is displayed.
2.
Run:
isis
[
process-id
]
The IS-IS view is displayed.
3.
Run:
timer lsp-max-age
age-time
The lifetime of an LSP is set.
When a switch generates an LSP, it sets the max lifetime for the LSP. After the LSP is
received by other switches, its lifetime decreases as time passes. If a switch does not receive
any updated LSP and the lifetime of this LSP decreases to 0, the lifetime of the LSP lasts
60s. If a new LSP is still not received, this LSP is deleted from the LSDB.
l
Configuring the Intelligent Timer Used to Generate LSPs
1.
Run:
system-view
The system view is displayed.
2.
Run:
isis
[
process-id
]
The IS-IS view is displayed.
3.
Run:
timer lsp-generation
max-interval
[
init-interval
[
incr-interval
] ]
[
level-1
|
level-2
]
The intelligent timer used to generate LSPs is set.
If no level is configured, both Level-1 and Level-2 are configured.
The initial delay for generating the same LSPs (or LSP fragments) is
init-interval
. The delay
for generating the same LSPs (or LSP fragments) secondly is
incr-interval
. When the routes
change each time, the delay for generating the same LSPs (or LSP fragments) is twice as
the previous value until the delay is up to
max-interval
. After the delay reaches
max-
interval
for three times or reset the IS-IS process, the interval is reduced to
init-interval
.
When
incr-interval
is not used and generating the same LSPs (or LSP fragments) for the
first time,
init-interval
is used as the initial delay. Then, the delay for generating the same
LSPs (or LSP fragments) is
max-interval
. After the delay reaches
max-interval
for three
times or the IS-IS process is reset, the interval is reduced to
init-interval
.
When only
max-interval
is used, the intelligent timer changes into a normal one-short timer.
l
Configuring the Size of an LSP
1.
Run:
system-view
S6700 Series Ethernet Switches
Configuration Guide - IP Routing
6 IS-IS Configuration
Issue 01 (2012-03-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
257