Figure 12-6
Tightening screws
2.
Connect the blue core wire labeled NEG(-) to the
-
port and the black/brown core wire
labeled RTN(+) to the
+
port on the tool-less female connector (pressfit type), and then
tighten the screws using a Phillips screwdriver, and then use a torque screwdriver to tighten
the M4 screws to 1.4 N·m (12.39 lbf·in.), as shown in
DANGER
Do not reversely connect the positive and negative poles. Reverse connection of positive
and negative poles may result in equipment malfunctions or personal injury. Therefore,
check the power cable connection before powering on the RRU.
Figure 12-7
Adding a tool-less female connector (pressfit type) to two core wires
Step 5
Strip the specified length of the sheath off the power cable to expose the intact shield layer, as
shown in
.
RRU3262
Installation Guide
12 Appendix
Issue 01 (2014-11-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
121