Figure 9-6
CPRI fiber optic cables routed through the cabinet (2)
Figure 9-7
FE/GE cables routed through the cabinet
l
If fiber optic cables need to be routed on the tower platform, lay out the cables on the
guardrail with the shortest distance and route the cables along the guardrail.
l
If fiber optic cables need to be routed close to a device on the tower, secure the cables to
the guardrail or pole with cable clips. The device cannot be far away from the position for
securing the cables.
l
If the fiber optic cables close to a device are too long, coil the excess of the cables and
secure them on the tower.
9.2 RRU Cable Connections
This section describes RRU cable connections.
NOTE
The RRU does not support power cable cascading.
shows the cable connections of a single RRU.
RRU3262
Installation Guide
9 Installing RRU Cables
Issue 01 (2014-11-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
94