![Huawei Quidway S3000-EI Series Operation Manual Download Page 330](http://html.mh-extra.com/html/huawei/quidway-s3000-ei-series/quidway-s3000-ei-series_operation-manual_169463330.webp)
Operation Manual - System Management
Quidway S3000-EI Series Ethernet Switches
Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-29
z
All modules are allowed to output information
II. Networking diagram
Switch
PC
Network
Switch
Switch
PC
Network
Figure 4-3
Schematic diagram of configuration
III. Configuration steps
1) Configuration
steps
# Enabling info-center
[Quidway] info-center enable
# Set the host with the IP address of 202.38.1.10 as the loghost; set the severity
level
threshold value as informational, set the output language to English; set all the modules
are allowed output information.
[Quidway] info-center loghost 202.38.1.10 facility local7 language english
[Quidway] info-center source default channel loghost log level informational
2)
Configuration on the loghost
This configuration is performed on the loghost.
Step 1: Perform the following command as the super user (root).
# mkdir /var/log/Quidway
# touch /var/log/Quidway/information
Step 2: Edit file /etc/syslog.conf as the super user (root), add the following
selector/actor pairs.
# Quidway configuration messages
local7.info /var/log/Quidway/information