Operation Manual - System Management
Quidway S3000-EI Series Ethernet Switches
Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-25
Note:
If you want to view the debugging information of some modules on the switch, you must
select
debugging
as the information type when configuring information source,
meantime using the
debugging
command to turn on the debugging switch of those
modules.
You can use the following commands to configure log information, debugging
information and the time-stamp output format of trap information.
Perform the following operation in system view:
Table 4-45
Configuring the output format of time-stamp
Operation
Command
Configure the output format of the
time-stamp
info-center timestamp
{
log | trap
|
debugging
} {
boot
|
date
|
none
}
Output time-stamp is disabled
undo info-center timestamp
{
log
|
trap
|
debugging
}
4)
Configuring of SNMP and network management workstation on the switch
You have to configure SNMP on the switch and the remote workstation to ensure that
the information is correctly sent to SNMP NM. Then you can get correct information
from network management workstation. SNMP configuration on switch refers to
Chapter 5 SNMP Configuration.
4.5.9 Turn on/off the Information Synchronization Switch in Fabric
After the forming of a Fabric by switches which support the XRN, the log, debugging
and trap information among the switches is synchronous. The synchronization process
is as follows: each switch sends its own information to other switches in the Fabric and
meantime receives the information from others, and then the switch updates the local
information to ensure the information coincidence within the Fabric.
The switch provides command line to turn on/off the synchronization switch in every
switch. If the synchronization switch of a switch is turned off, it does not send
information to other switches but still receives information from others.
1) Enable
info-center
Perform the following operation in system view.