![Huawei Quidway S3000-EI Series Operation Manual Download Page 322](http://html.mh-extra.com/html/huawei/quidway-s3000-ei-series/quidway-s3000-ei-series_operation-manual_169463322.webp)
Operation Manual - System Management
Quidway S3000-EI Series Ethernet Switches
Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-21
information with the level below it will not be output.
channel-number
specifies the
channel number and
channel-name
specifies the channel name.
When defining the information sent to log buffer,
channel
-
number
or
channel
-
name
must be set to the channel that corresponds to Console direction.
Every channel has been set with a default record, whose module name is
default
and
the module number is 0xffff0000. However, for different channels, the default record
may have different default settings of log, trap and debugging. When there is no
specific configuration record for a module in the channel, use the default one.
Note:
If you want to view the debugging information of some modules on the switch, you must
select
debugging
as the information type when configuring information source,
meantime using the
debugging
command to turn on the debugging switch of those
modules.
You can use the following commands to configure log information, debugging
information and the time-stamp output format of trap information.
Perform the following operation in system view:
Table 4-37
Configuring the output format of time-stamp
Operation
Command
Configure the output format of the
time-stamp
info-center timestamp
{
log | trap
|
debugging
} {
boot
|
date
|
none
}
Output time-stamp is disabled
undo info-center timestamp
{
log
|
trap
|
debugging
}
4.5.7 Sending the Configuration Information to Trap Buffer
To send configuration information to trap buffer, follow the steps below:
1) Enabling
info-center
Perform the following operation in system view.
Table 4-38
Enabling/disabling info-center
Operation
Command
Enable info-center
info
-
center enable
Disable info-center
undo info
-
center enable