If the RUN Indicator Is...
It Indicates that...
Then...
Steady on
There is power input, but the
board is faulty.
Disable the power supply,
rectify the board fault, and
then power on the pRRU
again.
Steady off
There is no power input.
Disable the power supply and
check the power input again.
On for 1s and off for 1s
The pRRU is running
properly.
End the power-on check task.
On for 0.125s and off for
0.125s
The board software is being
loaded.
If the loading is not complete
after 5 minutes, disable the
power supply. Check
whether the data in the
configuration file is correct.
Rectify the fault and then
power on the pRRU again.
----End
5.2 Powering Off the pRRU
A pRRU can be powered off in two ways: normal power-off and emergency power-off. You
need to perform a normal power-off in scenarios such as an equipment swap or foreseeable
regional blackout, and you need to perform an emergency power-off in emergencies such as a
fire, smoke, or water damage in indoor scenarios.
Procedure
l
Normal power-off
NOTICE
Powering off the pRRU interrupts services, and therefore perform associated operations
before a power-off.
–
If the pRRU is powered in PoE mode, remove the Ethernet cable.
–
If the pRRU is powered by an AC/DC adapter, disconnect the power cable of the AC/
DC adapter.
l
Emergency power-off
1.
Turn off the switch of the external power device.
----End
LampSite
Site Maintenance Guide
5 Powering On and Powering Off the pRRU
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15