4.1 Powering On the RHUB
The RHUB is powered by AC input.
Prerequisites
The power cable of the RHUB is not connected to power, that is, the power plug is removed.
Context
NOTICE
The RHUB must be powered on within 7 days after it is unpacked, and the period of its power-
off state cannot exceed 7 days during maintenance.
Procedure
Step 1
Insert the power plug to power on the RHUB.
Step 2
Wait 3 to 5 minutes. Then check the status of the RUN indicator.
If the RUN Indicator Is...
It Indicates that...
Then...
Steady on
There is power input, but the
board is faulty.
Disable the power supply,
rectify the board fault, and
then power on the RHUB
again.
Steady off
There is no power input, or an
alarm about the board is
reported.
Disable the power supply and
check the power input again.
If the power input is normal,
rectify the board fault, and
then power on the RHUB
again.
1s on and 1s off
The RHUB is running
properly.
End the power-on check task.
0.125s on and 0.125s off
The board software is being
loaded.
If the loading is not complete
after 5 minutes, disable the
power supply and check
whether the data in the
configuration file is correct.
Rectify the fault and then
power on the RHUB again.
----End
LampSite
Site Maintenance Guide
4 Powering On and Powering Off the RHUB
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11