The IP address of the iSCSI host port on the controller is in the format of
XXX.XXX.XXX.XXX
. For details on how to set the IP address of the iSCSI host port on the
controller, see "
3.7 Setting the iSCSI Host Port on the Controllers
".
NOTE
If the multipath software is installed on the AS side, you need to add
Multipath=portal
and
ConnfailTimeout=1
. The following information is displayed:
DiscoveryAddress=192.168.1.18
Multipath=portal
ConnfailTimeout=1
Step 9
Enter the command
:wq
to save the settings and exit from the file editing interface.
Step 10
Enter the command
/etc/init.d/iscsi restart
to restart iSCSI service.
NOTE
If the connection between ASs and the storage system succeeds to be set up, you can see
Port Connection
Status
of the AS displays
Connected
on the
Add Port
interface of the Web UI. For details, see "
3.10
Adding a Port
".
----End
3.10 Adding a Port
The host on the OSM3.0 interface cannot be mapped to an AS unless a port has been added to
it.
Prerequisite
CAUTION
When setting up the two-node system cluster environment, you need to add ports to the two
hosts created in "
3.4 Creating a Host Group
" and the two hosts with added ports correspond
to the cluster primary node and the cluster secondary node separately.
NOTE
l
Before adding a port to a host, ensure the system has a free port.
l
This system supports up to 256 ports.
Procedure
Step 1
On the OSM3.0 main interface, click
Mapping
. In the
Mapping
navigation tree, click a host.
The interface showing the information about the host is displayed. See
Figure 3-30
.
3 Configuring the Storage System
OceanStor S5600 Storage System
Initial Configuration Guide
3-38
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2009-09-30)