Usage Guidelines
When using this command, note the following items:
l
If the member disks of a RAID group contains coffer disks, the RAID group cannot be set
to hibernate.
l
The RAID groups in abnormal state cannot be set to hibernate.
Example
Set RAID group 0 to hibernate and the wait time to 10 minutes.
OceanStor: admin> chgcomsleep -o 2 -i 0 -t 1 -id 0
5.4.2 showcomsleep
Function
The command
showcomsleep
is used to query whether components are allowed to hibernate. If
allowed, query whether the components are in hibernation state and the wait time before
hibernation.
Format
showcomsleep
[
-i
raid id
]
-t
component type
Parameters
Keyword and Value
Description
Default Value
-i raid id
The RAID ID. The value
ranges from 0 to 31.
None.
-t component type
The component type. The
value can be 1 or 2, and is
described as follows:
l
1: The RAID.
l
2: The disk.
-i
is
unavailable.
None.
Modes
Normal mode.
Level
Super administrator level, administrator level and guest level.
5 Device Management Commands
OceanStor S2600 Storage System
Command Reference
5-12
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 07 (2010-05-20)