10.1 Setting Alarm Input and Output Parameters
Alarms can be linked by setting alarm input and output parameters.
Procedure
Step 1
Choose
Settings
>
Alarm Configuration
>
Alarm I/O
.
The page for
Alarm I/O
.
Figure 10-1
Alarm I/O tab page
Step 2
Set parameters. For detailed parameter description, see
Table 10-1
Parameter description
Parameter
Description
Alarm input
Device ID
ID of the alarm input device.
Enable
Indicates whether to enable
the alarm input function.
Name
User-defined device name.
Type
Select either
Normal open
or
Normal close
based on
the device status.
Alarm check interval
Time interval at which the
system checks for new
alarms.
Alarm output
Device ID
ID of the alarm output
device.
/
Manual control of the output
device status.
NOTE
This function cannot be used
with the alarm linkage
function. If the function is
used with the alarm linkage
function, the alarm linkage
actions will be affected.
Name
User-defined device name.
IPC6122-P
Configuration Guide