Usage Instruction
l
If the command contains
-d
, the setting is permanent and takes effect after a restart.
l
If the command does not contain
-d
, the setting is not permanent and will be restored to
the factory setting after a restart.
Example
# Set the rate limit of port eth2 to 50%.
[root@localhost tool]#
hinicadm rate -i eth2 -l 50
Set eth2 tx limit rate to 50% succeed
# Query the rate limit of port eth2.
[root@localhost tool]#
hinicadm rate -i eth2
eth2 tx limit rate: 50%.
eth2 default tx limit rate: 100%.
6.1.4.10 Querying the Chip and Optical Module Temperatures (temperature)
Function
The
temperature
command is used to query and set the chip and optical module temperatures
of a specified IN200.
Format
hinicadm temperature -i
<
devicename
>
Parameters
Parameter
Description
Value
devicename
Indicates the name of the
IN200 to be queried in the
system.
Example:
hinic0
and
hinic1
Usage Instruction
None
Example
# Query the chip and optical module temperatures of the IN200.
[root@localhost tool]#
hinicadm temperature -i hinic0
current temperature (unit: degree centigrade)
controller: 55
sfp1: 59
sfp2: absent
sfp3: NA
sfp4: 56
Huawei IN200 NIC
User Guide
6 Management Tools
Issue 06 (2019-07-27)
Copyright © Huawei Technologies Co., Ltd.
69