2.3.2.1 ALM-65538 EDFA High Temperature Alarm
Description
When the EDFA temperature exceeds the high temperature alarm threshold, an alarm is
generated.
Attribute
Alarm ID
Alarm Severity
Alarm Type
65538
Critical
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
OptModule
Index of the HFA
Case Temperature
Actual temperature of the HFA
Impact on the System
The EDFA service life is affected.
Possible Cause
The ambient temperature is excessively high or the ventilation is poor.
Handling Procedure
Decrease the ambient temperature.
Alarm Clearing Condition
When the EDFA temperature decreases to the high temperature alarm threshold minus 1, the
alarm is cleared (hysteresis range: 1°C).