2.3.1.4 ALM-65537 EDFA Output Power Alarm
Description
When the output optical power is lower than the preset alarm threshold, this alarm is
generated.
Attribute
Alarm ID
Alarm Severity
Alarm Type
65537
Major
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
OptModule
Index of the HFA
current output
optical power
Actual output optical power
Impact on the System
Services are affected.
Possible Cause
The output optical power is lower than the preset alarm threshold.
Handling Procedure
Check and reduce the output threshold.
Alarm Clearing Condition
When the output optical power exceeds the preset alarm threshold by 0.5 dB, the alarm is
cleared.