After 10 seconds, run the
display standby state
command on RouterA. The command
output shows that the BFD session status is ERR, and the status of backup interface
GigabitEthernet2/0/0 is Up, indicating that the backup interface is started.
<RouterA>
display standby state
Interface Interfacestate Backupstate Backupflag Pri
Loadstate
Backup-flag
meaning:
M---MAIN B---BACKUP V---MOVED U---
USED
D---LOAD P---
PULLED
------------------------------------------------------------------------------
--
Below is NQA
Information:
Instance Name BackupInterface
State
------------------------------------------------------------------------------
--
Below is BFD
Information:
Instance Name BackupInterface
State
test
ERR
GigabitEthernet2/0/0
OK
Run the
undo shutdown
command on GE2/0/0 of RouterB. After GE2/0/0 goes to Up,
wait 10 seconds and run the
display standby state
command on RouterA. The command
output shows that the BFD session status is
OK
and backup interface GigabitEthernet2/0/0
switches to the standby state.
<RouterA>
display standby state
Interface Interfacestate Backupstate Backupflag Pri
Loadstate
Backup-flag
meaning:
M---MAIN B---BACKUP V---MOVED U---
USED
D---LOAD P---
PULLED
------------------------------------------------------------------------------
--
Below is NQA
Information:
Instance Name BackupInterface
State
------------------------------------------------------------------------------
--
Below is BFD
Information:
Instance Name BackupInterface
State
test
OK
GigabitEthernet2/0/0
STANDBY
Huawei AR2200-S Series Enterprise Routers
Configuration Guide - Reliability
1 Interface Backup Configuration
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
38