Echo Passive : Disable Acl Number : -
Destination Port : 3784 TTL : 255
Proc Interface Status : Disable
WTR Interval (ms)
:
60000
Active Multi : 3
Last Local Diagnostic : No Diagnostic
Bind Application : No Application Bind
Session TX TmrID : - Session Detect TmrID : -
Session Init TmrID : - Session WTR TmrID : -
Session Echo Tx TmrID : -
PDT Index : FSM-0|RCV-0|IF-0|TOKEN-0
Session Description :
RouterA_to_RouterB
--------------------------------------------------------------------------------
Total UP/DOWN Session Number : 1/0
3.8 Globally Configuring the Destination Port Number for
the Multi-Hop BFD Control Packet
By configuring a global destination port number for multi-hop BFD control packets, you can
implement the interworking between the local device and a device running an earlier version,
and between a Huawei device and a non-Huawei device.
3.8.1 Establishing the Configuration Task
Before configuring a global destination port number for multi-hop BFD control packets,
familiarize yourself with the applicable environment, complete the pre-configuration tasks, and
obtain the required data. This can help you complete the configuration task quickly and
accurately.
Applicable Environment
The BFD control packet is encapsulated in the UDP packet for transmission, using the source
port in the range of 49152 to 65535 and destination port 3784 or 4784. According to the
RFC5883, the destination port 4784 is used for the multi-hop BFD control packet. On the
AR2200-S of the earlier version, however, destination port 3784 is used for the multi-hop BFD
control packet.
The destination port number of the multi-hop BFD control packet can be configured globally
according to the requirements:
l
To interwork with the device running the version earlier than the AR2200-S, the device
running the AR2200-S can be configured with destination port 3784 for the multi-hop BFD
control packet.
l
To interwork with the non-Huawei device, the device running the AR2200-S can be
configured with destination port 4784 for the multi-hop BFD control packet.
Pre-configuration Tasks
Before globally configuring the destination port number for the multi-hop BFD control packet,
complete the following tasks:
l
Installing the device and turning it on properly
l
Connecting interfaces correctly
Huawei AR2200-S Series Enterprise Routers
Configuration Guide - Reliability
3 BFD Configuration
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
162