COMBI521
EN - 119
DC Current with transducer clamp (In1 input – STD clamp)
Range [mV]
Resolution
[mV] Accuracy
-1999.9
-1.0
0.1
(5.0%rdg + 2dgt)
1.0
1999.9
Values lower to ±1mVDC are zeroed
AC TRMS Current with transducer clamp (In1 input – STD clamp)
Range [mV]
Frequency [Hz]
Resolution
[mV] Accuracy
1.0
2999.9
50/60Hz ±5%
0.1
(5.0%rdg + 2dgt)
Values lower to 1mVAC are zeroed ; Max crest factor: 3
DC/AC TRMS current with transducer clamp (In1 input – STD clamp)
FS clamp / Output ratio
Measurement range
Resolution
1A/1V AC
0.1mA ÷ 999.9mA AC
0.1mA AC
5A/1V AC
0.001A ÷ 4.999A AC
0.001A AC
10A/1V AC/DC
0.001A ÷ 9.999A AC/DC
0.001A AC/DC
30A/3V AC
0.01A ÷ 29.99A AC
0.01A AC
40A/400mV AC/DC
0.01A ÷ 39.99A AC/DC
0.01A AC/DC
100A/1V AC/DC
0.01A ÷ 99.99A AC/DC
0.01A AC/DC
200A/1V AC
0.01A ÷ 199.99A AC
0.01A AC
300A/3V AC
0.01A ÷ 299.99A AC
0.01A AC
400A/400mV AC/DC
0.1A ÷ 399.9A AC/DC
0.1A AC/DC
1000A/1V AC/DC
0.1A ÷ 999.9A AC/DC
0.1A AC/DC
2000A/1V AC
0.1A ÷ 1999.9A AC
0.1A AC
3000A/3V AC
0.1A ÷ 2999.9A AC
0.1A AC