6.4.0. RePlacing the thReaded MandRel
6.5.0. calibRatiOn
1
2 3
Remove the battery prior to working on the
riveting device. Release and remove casing (1).
To replace the threaded mandrel (2), pull back
the silver retention ring (3) and unscrew the
mandrel.
If the casing cannot be released manually, it can
be released using two SW24 wrenches.
Replace the mandrel and reassemble it in reverse
order.
To maintain a high quality standard and long service life, we recommend
annual calibration. This can be performed in conjunction with the general
maintenance and control of the tool.
The calibration can be performed by HS-Technik GmbH.
NOTICE
Comply with the following instructions when cleaning your
riveting device: Incorrect cleaning agents or procedures
when cleaning can lead to damage to the riveting device .