O
PERATING
Y
OUR
B
OILER (continued)
PAGE 43
______________________________________________________________________________________________________________________________________________________________________________________
REGULAR STOKING OF THE BOILER
HINT:
It is advantageous to have the wood that you are going to load ready and next to the
boiler before opening the by-pass damper. This will mean less smoke spillage into
the boiler room and less smoke up the chimney.
When re-stoking the boiler proceed as follows:
If The Draft Fan is
OFF
: (BOILER AT OPERATING TEMPERATURE)
CAUTION
: RISK OF WOOD GAS EXPLOSION
as explosive gases may be present.
1. OPEN THE BY-PASS DAMPER.
2. NEXT, TURN THE TIMER on the control panel fully clockwise. This will activate the draft
fan, overriding the operation control to help prevent the risk of a gas explosion when the
door is opened. Let the fan run for 2-3 minutes to vent the hot gases.
NOTE:
WHEN YOU ARE BURNING WOOD IN A TARM EXCEL, the operating aquastat
turns off the draft fan when the boiler gets up to temperature. This cuts the supply
of oxygen to the fire and the flame goes out. There remains, however, lots of hot
coals and a red hot refractory which will continue to bake the wood creating a build
up of hot gas in the firebox. Any person dealing with a Tarm EXCEL needs to keep
in mind that hot explosive gases may always be present. These gases are hot
enough to burn but without oxygen they can’t. If the draft fan is off for 15-20
minutes these gases will start to condense as creosote on the inner surfaces of the
firebox. However, if you open the load door when the gases are hot and explosive,
you may provide enough oxygen for a sudden back flash or puff (WOOD-GAS
EXPLOSION) to occur. This explains why you should
never open the load door
unless the fan has been running in the last few minutes
to vent hot explosive
gases from the firebox first.
3. Turn the draft fan off by switching the power switch to “OFF/RESET” on the control
panel.
4. Without delay, open the loading door 3/4” with your left hand.
5. Wait approximately 20 seconds.
6. Open the loading door slowly, fully, and cautiously!
7. Load the firebox if the previous load of wood has burned down to low coals, placing the
wood uniformly front to back and tight together, not crosswise. If the wood has not
burned down to low coals, do not load more wood.
8. Close the loading door.
9. Turn the draft fan back on by switching the power switch to “ON” on the control panel.
10. Close the by-pass damper.
43
Summary of Contents for 2000
Page 1: ......
Page 4: ......
Page 8: ... Intentionally left blank PAGE 4 4 ...
Page 13: ...FEATURES AND SPECIFICATIONS PAGE 9 9 ...
Page 28: ...FIELD WIRING DIAGRAMS PAGE 24 ...
Page 29: ...24 WIRING SCHEMATIC FOR CONTROLS PAGE 25 ...
Page 30: ...This is an insert page 25 ...
Page 63: ...TARM EXCEL CAUTION LABEL PAGE 58 58 ...
Page 65: ...BOILER Parts List PAGE 60 60 ...
Page 66: ...BOILER Parts List PAGE 61 61 ...