53
Code
PROGRAMMER LCD DISPLAY
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
88
Encoder Steps Count Fault
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.
1) Encoder Steps parameter does not
match the actual motor encoder.
Set:
Motor lost IFO control and
accelerated
without throttle command.
Clear:
Ensure the Encoder
Steps parameter matches the
actual encoder; cycle KSI.
89
Motor Type Fault
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake;
ShutdownPump.
1) The Motor_Type parameter value is
out of range.
Set:
Motor_Type parameter is
set to an illegal value.
Clear:
Set Motor_Type to
correct value and cycle KSI.
91
VCL/OS Mismatch
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.
1) The VCL software in the controller
does not match the OS software in the
controller.
Set:
VCL and OS software do
not match; when KSI cycles, a
check is made to verify that
they match and a fault is
issued when they do not.
Clear:
Download the correct
VCL and OS software into the
controller.