33
Level 1
Parameter
Level 2
Parameter
Units Parameter Range
Notes
Dual Drive
Dual Drive State
On/Off
On = A secondary controller has been detected in a dual
drive system
CAN Communication
BMS Communicating
On/Off
On = BMS is communicating to the controller through the
CAN Bus
Charger Communicating
On/Off
On = Charger is communicating to the controller through
the CAN Bus
Battery Information
Peak I&E
Peak RMS Current
AMP
0 to 1000
Peak RMS current reported while the system is under load
Minimum Voltage
Volt
0 to 170.0
Minimum voltage reported while the system is under load
General
Keyswitch Voltage
Volt
0 to 150
Voltage at KSI (Pin 1)
Measured Current
AMP
-600 to 600
The Measured System Current During Operation
Remaining Amphours AMP
0 to 500
Remaining Battery Amphours
BDI Percentage
%
0 to 100
Battery state of charge.
Aux Battery Voltage
Volt
0 to 20
Auxiliary battery voltage
Charging Info
Charger Output Current Ampere
0 to 100
Battery charger output current to the battery pack
Charger Output Voltage Volt
0 to 1400
Battery charger output voltage to the battery pack
Charger Status
N/A
0 to 32
Status of the charger.
Cell Monitor
Highest Cell
Identification of the battery with the highest voltage
Highest Cells Voltage Volt
0 to 4.500
Highest battery cell voltage
Lowest Cell
Identification of the battery with the lowest voltage
Lowest Cells Voltage
Volt
0 to 4.500
lowest battery cell voltage
Highest Temperature
°C
Highest battery temperature within the battery pack
Lowest Temperature
°C
Lowest battery temperature within the battery pack
Generic 532 Software Monitor Items