44
Code
PROGRAMMER LCD DISPLAY
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
43
Pot2 Wiper High
FullBrake.
1) See Monitor Menu >> Inputs: Pot2
Raw
2) Pot2 wiper voltage too high
Set
: Pot2 wiper (pin 17)
voltage is higher than the high
fault threshold (can be
changed with the VCL function
Setup_Pot_Faults()
)
Clear:
Bring Pot2 wiper voltage
below the fault threshold
44
Pot2 Wiper Low
FullBrake.
1) See Monitor Menu >> Inputs: Pot2
Raw
2) Pot2 wiper voltage too low
Set:
Pot2 wiper (pin 17)
voltage is lower than the low
fault threshold (can be
changed with the VCL function
Setup_Pot_Faults())
Clear
: Bring Pot2 wiper voltage
above the fault threshold
45
Pot Low Overcurrent
ShutdownThrottle;
FullBrake.
1) See Monitor Menu >> Outputs: Pot
Low
2) Combined pot resistance
connected to pot low is too low
Set
: Pot low (pin 18) current
exceeds 10mA
Clear
: Clear pot low
overcurrent condition and
cycle KSI