48
Code
PROGRAMMER LCD DISPLAY
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
68
VCL Run Time Error
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.
1) VCL code encountered a runtime
VCL error
2) See Monitor Menu >> Controller:
VCL Error Module and VCL Error. This
error can then be compared to the
runtime VCL module ID and error code
definitions found in the specific OS
system information file.
Set:
Runtime VCL code error
condition
Clear
: Edit VCL application
software to fix this error
condition; flash the new
complied software and
matching parameter defaults;
cycle KSI
69
External Supply Out of Range
1) External load on the 5V and 12V
supplies draws either too much or too
little current
2) Fault Checking Menu parameters
Ext Supply Max and Ext Supply Min are
mis-tuned
3) See Monitor Menu >> Options: Ext
Supply Current
Set:
The external supply
current (combined current
used by the 5V supply [pin 26]
and the 12V supply [pin 25]) is
either greater than the upper
current threshold or lower
than the lower current
threshold. The two thresholds
are defined by the External
Supply Max and External
Supply Min parameter
settings.
Clear:
Bring the external
supply current within range