Storage module LEDs
Storage module LEDs
The front panel and LED layout shown in the following illustration is an example. Depending on your specific model, the LEDs might be
different.
Item
Item LED
LED
Status
Status
Definition
Definition
1
Drawer status
Solid green
Drive drawer is closed
Flashing green Drive drawer is open
Flashing amber Thermal warning, close the drive drawer
2
UID
Solid blue
One or more drives are being located
Flashing blue
Firmware flash in progress
Off
No drives are being located
3
Health status
Green
Normal operation
Flashing amber Degraded condition
Flashing red
Critical condition
4
Drive status (in priority order) Solid amber
One or more drives failed
Flashing amber One or more drives are predicted to fail
Flashing green One or more drives are rebuilding or transforming
Solid green
One or more drives are members of a logical drive
Off
No drives are configured by a RAID controller
5
Drawer power
Green
Storage module is in use, do not remove
Off
Storage module is not in use, safe to remove
The drive drawer must be closed within five minutes after it is opened.
1
Storage module LEDs
98
Summary of Contents for Synergy 12000 Frame
Page 36: ...Customer self repair 36...
Page 37: ...Customer self repair 37...
Page 38: ...Customer self repair 38...
Page 39: ...Customer self repair 39...
Page 40: ...Removal and replacement procedures Removal and replacement procedures 40...
Page 53: ...HPE Synergy Console connections HPE Synergy Console connections 53...
Page 78: ...To replace the component reverse the removal procedure Removing and replacing a rear cage 78...
Page 82: ...Component and LED identification Component and LED identification 82...
Page 84: ...Information pull tabs 84...
Page 88: ...Figure 5 Optional horizontal half shelf Device bay partitions 88...
Page 92: ...Appliance bay numbering Appliance bay numbering 92...
Page 131: ...Specifications Specifications 131...
Page 134: ...Support and other resources Support and other resources 134...