To replace the component, reverse the removal procedure.
System battery replacement
System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery that provides
power to the real-time clock. If this battery is not properly handled, a risk of the fire and burns exists. To reduce the risk of
personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not expose the battery to extremely low air pressure as it might lead to explosion or leakage of flammable liquid or
gas.
• Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
• If the server no longer automatically displays the correct date and time, then replace the battery that provides power
to the real-time clock. Under normal use, battery life is 5 to 10 years.
Replace the system battery
Prerequisites
Before you perform this procedure make sure you have a small flat-bladed, nonconductive tool available.
Procedure
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
90
Removal and replacement procedures
Summary of Contents for ProLiant DL385 Gen10
Page 30: ...30 Customer self repair...
Page 31: ...Customer self repair 31...
Page 32: ...32 Customer self repair...
Page 129: ...8LFF front panel 12LFF front panel Midplane box LFF only Component identification 129...
Page 142: ...Boxes 2 and 3 to SAS Expander All boxes to SAS Expander 142 Cabling...
Page 143: ...Cable routing Midplane 4LFF SAS SATA drive option Cabling 143...
Page 145: ...Cable routing Rear 3LFF SAS SATA drive option for system board Cabling 145...
Page 147: ...Cable routing Front 2SFF NVMe side by side drive options Cabling 147...
Page 149: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 149...
Page 150: ...Box 3 150 Cabling...