Item
Description
Status
3
Do not remove LED
• Solid white = Do not remove the drive. Removing the drive
causes one or more of the logical drives to fail.
• Off = Removing the drive does not cause a logical drive to
fail.
4
Drive status LED
• Solid green = The drive is a member of one or more logical
drives.
• Flashing green = The drive is rebuilding or performing a
RAID migration, strip size migration, capacity expansion, or
logical drive extension, or is erasing.
• Flashing amber/green = The drive is a member of one or
more logical drives and predicts the drive will fail.
• Flashing amber = The drive is not configured and predicts
the drive will fail.
• Solid amber = The drive has failed.
• Off = The drive is not configured by a RAID controller.
NVMe SSD LED definitions
The NVMe SSD is a PCIe bus device. A device attached to a PCIe bus cannot be removed without allowing the device and
bus to complete and cease the signal/traffic flow.
CAUTION: Do not remove an NVMe SSD from the drive bay while the Do not remove LED is flashing. The Do not
remove LED flashes to indicate that the device is still in use. Removing the NVMe SSD before the device has
completed and ceased signal/traffic flow can cause loss of data.
Item
LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
2
Activity
ring
Rotating green
Drive activity
Off
No drive activity
Table Continued
132
Component identification
Summary of Contents for ProLiant DL385 Gen10
Page 30: ...30 Customer self repair...
Page 31: ...Customer self repair 31...
Page 32: ...32 Customer self repair...
Page 129: ...8LFF front panel 12LFF front panel Midplane box LFF only Component identification 129...
Page 142: ...Boxes 2 and 3 to SAS Expander All boxes to SAS Expander 142 Cabling...
Page 143: ...Cable routing Midplane 4LFF SAS SATA drive option Cabling 143...
Page 145: ...Cable routing Rear 3LFF SAS SATA drive option for system board Cabling 145...
Page 147: ...Cable routing Front 2SFF NVMe side by side drive options Cabling 147...
Page 149: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 149...
Page 150: ...Box 3 150 Cabling...