6.
Disconnect the Chassis Intrusion Detection switch cable from the system board.
7.
Remove the Chassis Intrusion Detection switch.
a.
Release the cable from the left DIMM guard
b.
Detach the switch from the left DIMM guard
To replace the component, reverse the removal procedure.
HPE Trusted Platform Module 2.0 Gen10 Option
The HPE Trusted Platform Module 2.0 Gen10 Option is not a customer-removable part.
CAUTION:
If the TPM is removed from the original server and powered up on a different server,
data stored in the TPM including keys will be erased.
If you suspect a TPM board failure, leave the TPM installed and remove the system board (
and replacing the system board
on page 81). Contact a Hewlett Packard Enterprise authorized service
provider for a replacement system board and TPM board.