Specification
Value
BTUs per hour
3067 at 100 VAC
2958 at 200 VAC
2949 at 240 VAC for China only
Power supply output
—
Rated steady-state power
800 W at 100 VAC to 127 VAC input
800 W at 100 VAC to 240 VAC input
800 W at 240 VDC input for China only
Maximum peak power
800 W at 100 VAC to 127 VAC input
800 W at 100 VAC to 240 VAC input
800 W at 240 VDC input for China only
HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply
Specification
Value
Input requirements
—
Rated input voltage
200 VAC to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
4.35 A at 200 VAC 3.62 A at 240 VAC
3.62 A at 240 VDC for China only
Maximum rated input power
851 W at 200 VAC
848 W at 240 VAC
848 W at 240 VDC for China only
BTUs per hour
2905 at 200 VAC
2893 at 240 VAC
2893 at 240 VDC for China only
Power supply output
—
Rated steady-state power
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only
Maximum peak power
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only