Environmental specifications
The following table lists the environmental specifications of HP Workstations.
Table 1-4
HP Workstation environmental specifications
Temperature
Operating
: 5 to 35°C (40 to 95°F)
Non-operating
: -40 to 60°C (-40 to 140°F)
NOTE:
Derate by one degree C (1.8 degrees F) for every 305m (1,000 ft.) altitude over 1,524m
(5,000 ft.).
Humidity
Operating
: 8 to 85% Relative Humidity (RH), non-condensing
Non-operating
: 8 to 90% Relative Humidity, non-condensing
Altitude
Operating:
0 to 3,048m (10,000 ft.)
Non-operating
: 0 to 9,144m (30,000 ft.)
Shock
Operating
: ½-sine: 40
g
, 2-3ms
Non-operating
:
●
½-sine: 160 cm/s, 2-3ms (~100
g
)
●
square: 422 cm/s, 20
g
NOTE:
Values represent individual shock events and do not indicate repetitive shock events.
Vibration
Operating Random
: 0.5
g
(rms), 5-300 Hz
Non-Operating
: random: 2.0
g
(rms), 10-500 Hz
NOTE:
Values do not indicate continuous vibration.
8
Chapter 1 Workstation overview