Item
Component
Description
4
Drive status LED
• Off—The drive is not configured by a RAID controller
• Solid green—The drive is a member of one or more logical
drives.
• Flashing green (4 Hz)—The drive is operating normally and has
activity.
• Flashing green (1 Hz)—The drive is rebuilding or performing a
RAID migration, stripe size migration, capacity expansion,
logical drive extension, or is erasing.
• Flashing amber/green (1 Hz)—The drive is a member of one or
more logical drives that predicts the drive will fail.
• Solid amber—The drive has failed.
• Flashing amber (1 Hz)—The drive is not configured and predicts
the drive will fail.
5
Adapter ejection release latch
and handle
Removes the SFF flash adapter when released
NVMe SSD components
The NVMe SSD is a PCIe bus device. A device attached to a PCIe bus cannot be removed without allowing
the device and bus to complete and cease the signal/traffic flow.
CAUTION:
Do not remove an NVMe SSD from the drive bay while the Do Not Remove button LED is flashing. The
Do Not Remove button LED flashes to indicate the device is still in use. Removal of the NVMe SSD
before the device has completed and ceased signal/traffic flow can cause loss of data.
1
2
3
4
Item
Description
1
Release lever
2
Activity ring
3
Do Not Remove button
4
Power button
10
NVMe SSD components