Basic Troubleshooting
159
Network Storage Router e1200-160
Verifying PRLI Data
The router returns the PRLI (preliminary login) response data as specified in
Table 12
.
In the default configuration, the router returns PRLI Data (PRLI Accept Payload)
with the Target bit SET and the Initiator bit CLEAR. However, some
configurations require the Initiator bit be SET, such as in router-to-router
configurations. See the Fibre Channel Overrides Menu for more information
about changing the initiator bit.
Table 12: PRLI
Item
Value
PRLI Command Code
0x20
Page Length
0x10
Payload Length
0x10
Type Code
0x8
Type Code Extension
0x0
OPA
0x0
RPA
0x0
IPE
0x1
Response Code
0x1
Originator Process Associator
0x0
Responder Process Associator
0x0
Initiator Function
0x1
Target Function
0x1
Command/Data Mixed Allowed
0x0
Data/Response Mixed Allowed
0x0
Read XFER_RDY Disabled
0x1
Write XFER_RDY Disabled
0x0
Summary of Contents for StorageWorks e1200-160
Page 8: ...Contents 8 Network Storage Router e1200 160 ...
Page 16: ...About this Guide 16 Network Storage Router e1200 160 ...
Page 34: ...Configuration Overview 34 Network Storage Router e1200 160 ...
Page 88: ...Visual Manager User Interface 88 Network Storage Router e1200 160 ...
Page 144: ...Serial Telnet User Interface 144 Network Storage Router e1200 160 ...
Page 166: ...Serial and Ethernet Pin Assignments 166 Network Storage Router e1200 160 ...
Page 172: ...Controller LUN Commands 172 Network Storage Router e1200 160 ...
Page 178: ...Addressing Methods and Table Structures 178 Network Storage Router e1200 160 ...
Page 183: ...Regulatory Compliance Notices 183 Network Storage Router e1200 160 Japanese Notice ...
Page 186: ...Regulatory Compliance Notices 186 Network Storage Router e1200 160 ...