HP StorageWorks 7100 - Virtual Array Appendix Download Page 22

FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con
 

Error! No text of specified style in document. 

Event 

Number 

(dec/hex) 

Event 
Name 

Logged? 

Predictive 

Maintenance 

Implication 

Suspected 
Components 

Mf

g Fail? 

Description 

460/0x1cc 

TWSI Write Failure 

 

Controller, 
battery, power-
supply, 
midplane 

The two-wire serial bus module retried the write and 
was either not able to get a response from the 
device, the transaction failed, or the bus failed.  In 
the case of a bus failure, the bus was good at the 
time the read request was made.  Now it has failed. 

461/0x1cd 

TWSI transmit Failure 

 

Controller, 
battery, power 
supply, 
midplane 

The two-wire serial bus module retried the transmit 
and was either not able to get a response from the 
device, the transaction failed, or the bus failed.  In 
the case of a bus failure, the bus was good at the 
time the read request was made.  Now it has failed. 

462/0x1ce 

EEPROM now present 

 

 

The eeprom was marked as not present because of 
"no hardware" status from the TWSI module.  Upon 
further attempts to communicate, the device is now 
responding. 

463/0x1cf 

EEPROM new status 

 

 

The status (GOOD, NOT_PRESENT, FAILED, 
CRITICAL) has changed. 

464/0x1d0 

EEPROM Selftest Passed 

 

Midplane 

The eeprom selftest was able to verify that the 
midplane eeproms are mirrored. 

465/0x1d1 

EEPROM Selftest Failed 

 

Midplane 

The selftest of the mirrored eeproms detected the 
data was not identical between the pair.  An attempt 
to fix this inconsistancy failed. 

466/0x1d2 

EEPROM Read Failed 

 

Midplane 

The firmware was not able to read correctly from 
either of the mirrored midplane eeproms. 

467/0x1d3 

EEPROM Write Failed 

 

Midplane 

The firmware was not able to read correctly from 
either of the mirrored midplane eeproms. 

468/0x1d4 

EEPROM not mirrored 

 

Midplane 

The firmware was not able to read or write correctly 
from one of the mirrored midplane eeproms.  The 
system is no longer fully redundant. 

469/0x1d5 

EEPROM can not get wwn 

 

Midplane 

During a request for a new lun WWN, the firmware 
was not able to read from either of the midplane 
eeproms.  This is can be due to a variety of TWSI 
failures or the eeprom failing.  The eeprom can only 
create 2,000 trillion (2 quadrillion) LUN’s.  If this 
limit has been exceeded, the midplane must be 
replaced. 

470/0x1d6 

Firmware clone complete 

 

N.A. 

Cloning of firmware to the other controller has 
completed. 

471/0x1d7 

Firmware clone failed. 

Controller or 

midplane 

N.A. 

Cloning of firmware to the other controller has 
failed. 

472/0x1d8 

VSC7130_INT_DISABLE_EH Y 

 

VSC7130 
Signal Detect / 
Port Bypass 
Control chip 

We’ve exceeded the maximum number of retries in 
attempting to clear a VSC7130 signal detect 
interrupt.  The interrupt is being disabled to allow 
other TWS devices sharing the interrupt line to be 
able to generate interrupts.  When this condition 
exists, the controller will not be able to respond to 
JBOD cable insertion and removal instantaneously, 
instead it will take up to five seconds to recognize 
the state change.  This condition generally indicates 
bad FC conditions or a problem with the 7130. 

473/0x1d9 

LCC_DEVICE_STATE_INV
ALID_EH 

 

LCC/ESD 

Happens when a JEM is no longer allowed to send 
requests to an LCC its retries are zeroed.  The 
current outstanding I/O may complete but no 
additional I/O will be started. 

474/0x1da 

LCC_EVENT_EH 

 

LCC/ESD 

Status of elements as well as information on the 
LCC. 

475/0x1db 

LCC_DATA_LENGTH_ERR
OR_EH 

 

LCC/ESD 

The amount of data sent by the LCC was not what 
was expected or calculated. 

476/0x1dc 

LCC_NOT_SUPPORTED_ER
ROR_EH 

 

LCC/ESD 

Data that was received from the LCC was not 
supported.  e.g. LCC F/W not supported or a NEW 
element type is not supported by the array F/W. 

477/0x1dd 

LCC_RETRIES_EXCEEDED
_EH 

 

LCC/ESD 

The retries for an I/O have been exceeded. 

478/0x1de 

LCC_ELEMENT_EXCEEDE
D_MAX_EH 

 

LCC/ESD 

The number of elements ,for a specific element type, 
exceeded the maximum allowed.  (e.g. Disk element 
type reports 60 drives in a single JBOD) 

479/0x1df 

LCC_STORAGE_EXCEEDE
D_EH 

 

LCC/ESD 

Exceeded element or status storage space. 

480/0x1e0 

LCC_JEM_DELETE_DONE_

 

LCC/ESD 

Topology Manager requested a delete of a JEM.  

Summary of Contents for StorageWorks 7100 - Virtual Array

Page 1: ... array changes to the configuration of the array performance data port error statistics Table 1 lists all event codes that can appear in the controller log event pages The table also includes events that are not logged but can still generate SCSI sense data Appropriate corrective action is included for all events that require it Many events are informational and require no action on the part of th...

Page 2: ...are error during a selftest operation 13 0xd Commands Cleared Unit Attention N N A None N Another originator sent commands to the array that resulted in commands being cleared for the current originator 14 0x0e Mode Parameters Changed Unit Attention N N A None N Another initiator sent commands to the array that resulted in shared mode parameters being changed for the current initiator 15 0x0f Unco...

Page 3: ...A None Y A disk drive failed the reconfiguration attempt TUR inquiry mode sense mode select read capacity The PDD attempted a device reconfiguration after the device was reset during the normal course of operation i e not during a hotplug of this drive but possibly during a hotplug of another drive If the device reconfiguration fails the PDD flushes all non passthru I Os from its waiting queue wit...

Page 4: ... 0x2c Invalid RG ID N N A None N A command that specifies an Redundancy Group ID specified one that is invalid for the current subsystem configuration 45 0x2d Shutdown Failed N N A None N CFM could not shutdown the subsystem because no volume set members were present all members missing 46 0x2e Not Enough Space Y Ignore See accompanying errors None Y A write command had to move data in order to fi...

Page 5: ...See accompanying errors None N R1 detected that the devices necessary for a write were not available for access before the access was attempted This can apply to an initial attempt to write or to a retry 59 0x3b Disk Interface Error Y N A None Y An error occurred on a disk interface command 60 0x3c Unsupported feature N Ignore Device Management error None Y An attempt was made to install a license...

Page 6: ...uld retry the operation 78 0x4e Silent Disk Drive Error Recovery N N A None N On a previous attempt s the drive failed the I O Usually due to hot plug The PDD retried the I O and the drive returned good status We do not log a recovered error because the original error was not logged We report GOOD status to the host 79 0x4f Check Condition From Disk Drive With No Sense Y Single Occurrence Disk Dri...

Page 7: ...troller does not have sufficient information to determine the extent of the damage 94 0x5e Volume Set Missing During Recovery Y ignore operator error None Y The volume set referenced in a recover command is not present in the subsystem If a NULL volume set was referenced then this error indicates that no members of any volume set were present This error can also result from imcompatible stamp vers...

Page 8: ...ermission to access LUN None Y The Host attempted to perform an operation on LUN without having an appropriate access permission 112 0x70 Host can not be authenticated to access LUN Security map Y Ignore Provide correct password None N The Host failed the authentication for access to LUN Security map because the password that it presented is incorrect 113 0x71 Limit to Maximum number of Principals...

Page 9: ...pected error 131 0x83 Disk Interface Command Failed Y N A None N A command to a backend device failed due to an error that does not include sense data from the device 132 0x84 Host is not authorized to access LUN Y Ignore Host doesn t have permission to access LUN None Y LUN Security Authoriztion failed Host attempted to perform an operation on a LUN without having an appropriate access permission...

Page 10: ...leted successfully This message follows the message 267 0x10b Insufficient Space To Start Rebuild Y Ignore See accompanying errors None N here is insufficient disk space for rebuild to execute This message followsthe message and may follow the REBUILD message 268 0x10c Rebuild Failed Y Ignore See accompanying errors None N ebuild has failed to complete due to multiple disk failures or a controller...

Page 11: ...ification succeeds 279 0x117 Disk Set Attached Y Ignore Operator activity None N This error code indicates the system state change consisting of attachment to a new volume set has occurred This occurs after every format subsystem and whenever a power on or reset occurs while the controller is not attached to a volume set In some cases the currently attached volume set may be empty 280 0x118 Reset ...

Page 12: ...ta may then be successfully migrated 290 0x122 Warm Boot IO Expander Fault Y Ignore if recovered by power cycle Controller Y This error code indicates that the IO Expander containing the warm boot bit did not power on in the correct default condition or that attempts to set the warm boot bit in the IO Expander failed 291 0x123 Disk Set Detached Y Ignore Operator Host activity None N This is a syst...

Page 13: ...r This error is logged only once per power on 303 0x12f No Interrupts From Other Controller Y Single Occurrance Controller Backplane N he other controller interrupt seems to be broken The timer interrupt fired multiple times with new communication messages but no other controller interrupts were present This error is logged only once per power on 304 0x130 Disk Interface Disconnect Y Ignore Disk c...

Page 14: ...an expected 319 0x13f Disk Interface Overrun Event Y Single Occurrance not with other entries Disk controller disk interface N An attached disk sent received more data than expected 320 0x140 Disk Interface Timeout Event Y 2 occurrances per hot plug insert or removal Disk controller disk interface N A command to an attached disk did not complete within the allotted time 321 0x141 Controller ECC Mi...

Page 15: ...6 0x150 Disk Interface State Event Y Single Occurrance not with other entries Controller disk disk interface N The disk interface controller and or software state information was incorrect for observed interface activity 337 0x151 Uncorrectable ECC Error During Initialization Y 1 in 6 months if no operator activity SIMM Controller N This error code indicates that the system experienced a unrecover...

Page 16: ...50 0x15e RAM Version Mismatch Y N A None N The upload routine was unable to upload part of the disk NVRAM image because the current firmware does not support that use of RAM Most likely an older version of firmware is trying to upload a disk image posted by some other firmware version 351 0x15f Disk Format Version Mismatch Y N A None N The NVRAM format of the disks does not match the format used b...

Page 17: ... This error code indicates that some non fatal error appeared in the shared memory error queue The two words of this queue entry will be placed in the log entry extended info area 363 0x16b Shared memory controller error Y Ignore if recovered by reset or power cycle Controller N This error code indicates that some fatal error appeared in the shared memory controller error queue The two words of th...

Page 18: ...376 0x178 Frontend Fibre Channel Event Y Ignore None N This error code indicates that the Front End Fibre Channel port had an event that it has logged Specific information about the event is placed in the extended info area of the log 377 0x179 Frontend Services Event Y Ignore None N This error code indicates that a Front End Services FES event has occurred and has been logged Specific information...

Page 19: ...en inserted into the enclosure 388 0x184 Internal drive removed Y Disk internal to the controller enclosure N An internal disk has been removed from the enclosure 389 0x185 Internal drive requesting port bypass Y Disk internal to the controller enclosure N An internal disk is requested that its FC port be bypassed 390 0x186 Internal drive has stopped requesting port bypass Y Disk internal to the c...

Page 20: ...ler will be failed 419 0x1a3 VSC055 Interrupt Clear Failed Y VSC055 IO Expander Chip Y An attempt to clear an interrupt on the VSC055 indicated in the event extended information has failed The controller will be failed 420 0x1a4 Power supply was inserted Y Power Supply N The power supply has been inserted into the enclosure 421 0x1a5 Power supply status is GOOD Y Power Supply N The power supply ha...

Page 21: ... charge is equal or higher than a specified threshold value 448 0x1c0 NVRAM battery status is UNKNOWN Y NVRAM battery N The status of the NVRAM battery is unknown This may be due to the firmware not being able to communicate with the battery 449 0x1c1 TWSI bus has been requested by another module Y Ignore unless occurring frequently Controller battery power supply N The battery management firmware...

Page 22: ...wn Y Midplane Y During a request for a new lun WWN the firmware was not able to read from either of the midplane eeproms This is can be due to a variety of TWSI failures or the eeprom failing The eeprom can only create 2 000 trillion 2 quadrillion LUN s If this limit has been exceeded the midplane must be replaced 470 0x1d6 Firmware clone complete Y N A N Cloning of firmware to the other controlle...

Page 23: ...tected an internal error 489 0x1e9 abterm reset Y controller N This event code indicates that the controller reset due to an abnormal termination in the firmware 490 0x1ea front panel reset Y controller N This event code indicates that the controller reset due to a request through the front panel 491 0x1eb host reset Y controller N This event code indicates that the controller reset due to a reque...

Page 24: ...ta on the two eeproms at a given location was different This problem is usually fixed if the firmware can write to the eeproms 510 0x1fe FC Signal Detect Interrupt Y VSC7130 PBC Dual Repeater Chip N An interrupt on one of the VSC7130 port bypass control signal detect chips has occurred See the extended information for details 511 0x1ff Dual controller clock sync error Y controller N An interrupt f...

Page 25: ...Y Ignore unless no Operator activity Disk Drive Back End FC Link N An AutoFormat event was logged this is caused either by a backend format of an internal drive beginning or completing Look as the associated data for drive and status 532 0x214 Power supply is not connected to an AC source Y Power Supply Y This warning indicates that the power supply is not connected to an AC source 533 0x215 Some ...

Page 26: ...out Y Ignore Lab only none N The cross controller lock module failed to grant the decoder s lock in exclusive mode within the allowed period after an obtain request was deferred This may indicate a deadlock in the system or that the system is too busy 552 0x228 Decoder lock request was deferred Y Ignore Lab only none N The cross controller lock module deferred a request to obtain the decoder s loc...

Page 27: ... mode parameters region contains a revision that is older than the revision expected by current firmware As a result some mode parameters were set to their default values since there was no saved value present in the EEPROM 577 0x241 Start multi disk loss scan Y Ignore should be other prior failure events controller N A backend scan was started to detect a multiple disk loss condition because of a...

Reviews: