FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con
Error! No text of specified style in document.
Table 1. Controller Log Event Code Descriptions
Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
0/0x0
No Sense
N
N.A.
None
N
No sense data is available.
1/0x01
Undefined
N
N.A.
None
N
Undefined event code.
2/0x02
Unsupported LUN Capacity
N
N.A.
None
N
An attempt was made to create a LUN with an
unsupported capacity. The capacity was either zero
or was greater than the maximum LUN capacity
supported by the subsystem.
3/0x03
Parameter List Length Error
N
N.A.
None
Y
The length of the parameter list was incorrect for the
command and it’s parameters.
4/0x04
Invalid Field In Parameter List
N
N.A.
None
Y
One or more of the fields in the parameter list
contained an invalid value.
5/0x05
No Physical Device Present
N
N.A.
None
Y
A command attempted to access a device (disk or
enclosure controller) that is not currently present in
the subsystem.
6/0x06
Invalid Opcode
N
N.A.
None
Y
The opcode in the command that was received is not
supported by the subsystem. This error could be
due to the LUN Security configuration.
7/0x07
Invalid Bit In CDB
N
N.A.
None
Y
One or more fields in the CDB contained an illegal
or unsupported value.
8/0x08
Logical Block Address Out Of
Range
N
N.A.
None
Y
The LBA specified in the command was out of
range for the LUN that it was sent to.
9/0x09
Not Ready
N
N.A.
None
N
The array is not ready to process the command that
was received. Furthermore, the array will not
become ready until an initializing command is
received and successfully processed.
10/0x0a
Undefined
N
N.A.
None
N
Undefined event code.
11/0x0b
Power On Unit Attention
N
N.A.
None
N
The array just completed a reset operation.
12/0x0c
Hardware Error Unit Attention
N
N.A.
None
Y
The most recent reset operation detected a hardware
error during a selftest operation.
13/0xd
Commands Cleared Unit
Attention
N
N.A.
None
N
Another originator sent commands to the array that
resulted in commands being cleared for the current
originator.
14/0x0e
Mode Parameters Changed
Unit Attention
N
N.A.
None
N
Another initiator sent commands to the array that
resulted in shared mode parameters being changed
for the current initiator.
15/0x0f
Unconfigured LUN
N
N.A.
None
N
The LUN to which the command was sent is
currently not configured for use.
16/0x10
Invalid Target LUN
N
N.A.
None
N
The subsystem does not support the LUN that was
specified in the most recent command. The LUN is
the target of the requested action.
17/0x11
Invalid Source LUN
N
N.A.
None
N
The subsystem does not support the LUN that was
specified in the most recent command. The LUN is
the source of the requested action.
18/0x12
Not Enough Space
Y
Ignore
None
Y
A write command had to move data in order to find
enough space to complete. Errors were encountered
during this process which precluded the controller
from providing enough space for the write. This
would generally result from multiple failing or
missing drives. This failure can also result from
faulty space management logic in the controller.
19/0x13
Command Illegal In Current
State
N
N.A.
None
N
The current subsystem state precludes processing of
the requested command.
20/0x14
Becoming Ready
N
N.A.
None
N
The subsystem is not ready to process the command
that was received. However, it is in the process of
becoming ready and will be able to process that
command soon.
21/0x15
Recovered With Low Level
Retries
Y Ignore Disk,
controller, disk
interface
N
On a previous attempt(s), the drive failed the I/O.
The PDD retried the I/O and the drive returned good
status. PDD stands for Physical Device Driver.
Specifically this error indicates that the RAID
implementation was not involved in the retries.
22/0x16
Recovered By Disk Drive
Y
See information
provided by
drive vendor
Disk Drive
N
The disk drive returned a status of
CHECK_CONDITION, RECOVERED_ERROR.
23/0x17
Disk Drive Media Error
Y
See information
Disk Drive
N
The disk drive returned a status of