Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
by a 0 indicates that the device number has not yet
been assigned.
273/0x111
Disk Drive Added To Disk Set
Y
Ingore - Operator
activity
None
N
This error code indicates the system state change
consisting of the addition of a new volume set
member. This occurs only when a drive that was
not previously a member becomes a member. It
does NOT occur then down, failed, or missing
drives are returned to good standing. The device
number of the drive added appears in this change
record.
274/0x112
Disk Drive Removed
Y
Ignore unless no
Operator activity
Disk Drive,
Back End SCIS
Bus, Controller
N
This error code indicates the system state change
consisting of a hot plug removal. This event occurs
for volume set members only. The device number
of the drive removed appears in this change record.
A device number consisting of the controller serial
number followed by a 0 indicates that the device
number has not yet been assigned.
275/0x113
Disk Drive Deleted From Disk
Set
Y
Ignore - Operator
activity or
assocaited errors
None
N
This error code indicates the system state change
consisting of the deletion of a new volume set
member. This occurs only when a drive that was
previously a member becomes a non-member. The
drive may or may not be present in the subsystem at
the time. The device number of the drive added
appears in this change record.
276/0x114
Logical Unit Created
Y
Ignore - Operator
or host activity
None
N
This error code indicates the system state change
consisting of the creation of a new SCSI LUN. This
change occurs only if LUN creation succeeds.
277/0x115
Logical Unit Deleted
Y
Ignore - Operator
or Host activity
None
N
This error code indicates the system state change
consisting of the deletion of an existing SCSI LUN.
This change occurs only if LUN deletion succeeds.
278/0x116
Logical Unit Modified
Y
Ignore - Host
Activity
None
N
This error code indicates the system state change
that occurs when an existing LUN is modified. This
change occurs only if LUN modification succeeds.
279/0x117
Disk Set Attached
Y
Ignore - Operator
activity
None
N
This error code indicates the system state change
consisting of attachment to a new volume set has
occurred. This occurs after every format subsystem
and whenever a power on or reset occurs while the
controller is not attached to a volume set. In some
cases the currently attached volume set may be
empty.
280/0x118
Reset To Clear VSC7130
interrupt
Y
Ignore - unless
repeated
VSC7130 - on
controller
Y
This error code indicates that VSC7130 interrupt
could not be cleared. The controller was reset in an
effort to clear the interrupt.
281/0x119
Unable To Recreate Memory
Error
Y
Ignore
None
N
This error code indicates that the system
experienced a memory error and was unable to
recreate the failed memory accesses. An excessive
number of un-reproducible memory errors will
result in a controller failure.
282/0x11a
Memory Error Not Recovered
With Redundancy
Y
> 1 in 6 mo.
SIMM,
Controller,
Backplane
Y
This error code indicates that the system
experienced a unrecoverable error that could not be
recovered via redundant memory. This will cause
information loss if the error occurs in non-redundant
NVRAM memory.
283/0x11b
Memory Error Recovered With
Redundancy
Y
Ignore - See
accompanying
errors
None
N
This error code indicates that the system
experienced a unrecoverable error that could be
recovered via redundant memory or a controller
reset
284/0x11c
Uncorrectable Memory Error
Y
> 1 in 6 months
per controller
Controller,
SDRAM,
midplane
Y
This error code indicates that the system
experienced a uncorrectable shared-memory error.
The two word queue entry found in the shared-
memory controller error queue will be placed in the
event extended info area. After all entries currently
in the queue have been processed, the subsystem
will undergo a short reset at which time an attempt
will be made to correct the error using the mirrored
copy of memory (if available).
285/0x11d
Correctable Memory Error
Y
See correctable
rate assocaited
with usage page
SDRAM,
controller,
midplane
Y
This error code indicates that the system
experienced a correctable shared-memory error.
The two word queue entry found in the shared-
memory controller error queue will be placed in the
event extended info area. After all entries currently