Table 4-12 identifies PCI-X Hot Plug slot activity status according to LED description.
Table 4-12: Internal and External PCI-X Expansion Slot LEDs
LED State
OK to
Open
Slot Status
Power
Fault
On
Off
No
Power is currently applied to the slot. Do
not
open the
expansion slot latch. The slot is functioning normally.
Power
Fault
On
On
No
Power is currently applied to this slot, but the
slot needs
attention
for a possible problem with the slot, expansion
board, or driver. Do
not
open the expansion slot latch.
Power
Fault
Flashing
On or
Off
No
The power slot is being turned off or on, which may take
several minutes. Do
not
open the expansion slot latch.
Press the PCI-X Hot Plug button to cancel the operation.
Power
Fault
Off
On
Yes
Power to this slot is turned off, but this
slot needs
attention
. A problem may exist with the slot, expansion
board, or driver.
Power
Fault
Off
Off
Yes
The power to the slot is off. An expansion board may be
installed in this slot.
Note:
If any of the LEDs indicates an error, refer to the
HP ProLiant ML570 Generation 2 Server
Setup and Installation Guide
for more information.