Component identification 13
Hot-plug drive LED definitions
Item LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an
update.
2
Activity ring
Rotating green Drive activity
Off
No drive activity
3
Do not remove Solid white
Do not remove the drive. Removing the drive causes one or
more of the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
The blue Locate LED is behind the release lever and is visible when illuminated.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot
Mode. It cannot be enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled,
drives connected to the system board Mini-SAS connectors operate in AHCI or Legacy mode.
Under this condition:
•
The drives cannot be a part of a hardware RAID or a logical drive.
•
The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("
" on page
) to enable or disable the B140i controller (System Configuration
→
BIOS/Platform Configuration (RBSU)
→
System Options
→
SATA Controller Options
→
Embedded SATA Configuration).
Summary of Contents for ProLiant DL60 Gen9
Page 14: ...Component identification 14 Fan locations ...
Page 22: ...Operations 22 o Secondary PCI riser cage o PCI blank ...
Page 86: ...Cabling 86 FBWC module slot 1 cabling FBWC module slot 2 cabling ...
Page 87: ...Cabling 87 FBWC module slot 3 cabling Smart Storage battery cabling ...
Page 117: ...Support and other resources 117 ...