Removal and replacement procedures 38
2.
Remove the component as indicated:
To replace the component, slide the component into the bay until it is fully seated.
Hot-plug fan
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server.
The server shuts down in the following temperature-related scenarios:
•
At POST:
o
The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the
cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly
shutdown and enters Standby mode.
o
The BIOS performs an orderly shutdown if two or more fans have failed.
o
The server performs an immediate shutdown if it detects a critical temperature level.
IMPORTANT:
An immediate shutdown is a hardware-controlled function and it overrides any
firmware or software actions.
•
In the operating system:
o
The Health Driver performs an orderly shutdown if it detects a cautionary temperature level. If the
server detects a critical temperature level before the orderly shutdown occurs, the server performs
an immediate shutdown. Additionally, the Health Driver performs an orderly shutdown if more
than one fan is failed or removed.
o
When Thermal Shutdown is disabled in RBSU, the server performs an immediate shutdown if it
detects a critical temperature level.
IMPORTANT:
An immediate shutdown is a hardware-controlled function and it overrides any
firmware or software actions.
To remove the component:
1.
Extend or remove the server from the rack ("
Remove the server from the rack
" on page
31
).
Summary of Contents for ProLiant DL380 G5 DPSS
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 16: ...Customer self repair 16 ...
Page 72: ...Removal and replacement procedures 72 14 Install the power supplies 15 Power up the server ...
Page 74: ...Cabling 74 Fan board cabling Hard drive backplane power cabling ...
Page 76: ...Cabling 76 Systems Insight Display cabling ...
Page 94: ...Component identification 94 Only the 12 fan configuration supports all connectors ...