Removal and replacement procedures 55
Capacitor pack
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
To remove the component:
1.
Power down the server (on page
29
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
30
).
o
Remove the server from the rack (on page
31
).
4.
Remove the access panel ("
Access panel
" on page
35
).
5.
If the cache module is installed on the system board, remove the PCI riser cage ("
PCI riser cage
" on
page
50
).
6.
If the existing cache module is connected to a capacitor pack, observe the FBWC module LEDs:
o
If a backup is in progress, wait for the backup to complete.
o
If the backup is complete, or if the cache has failed, remove the controller from the server, and then
continue with the next step.
7.