Removal and replacement procedures 38
3.
Do one of the following:
o
Extend the server from the rack (on page
28
).
o
Remove the server from the rack (on page
30
).
4.
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
5.
Open the locking latch.
The access panel slides back, releasing it from the chassis.
6.
Lift and remove the access panel.
To replace the component, reverse the removal procedure.
4-bay and 8-bay LFF non-hot-plug drive cable
assemblies
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
1.
Power down the server (on page
27
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
If installed, remove the security bezel ("
Remove the security bezel (optional)
" on page
27
).
4.
Remove all drives ("
Non-hot-plug drive
" on page
34
) and drive carriers ("
Non-hot-plug drive carrier
" on
page
34
).
Summary of Contents for ProLiant DL180 Gen9
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 23: ...Illustrated parts catalog 23 ...
Page 121: ...Cabling 121 Item Description 3 USB 3 0 connector cable ...