Removal and replacement procedures 35
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1.
Back up all server data on the drive.
2.
Power down the server (on page
27
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
If installed, remove the security bezel ("
Remove the security bezel (optional)
" on page
27
).
5.
Remove the non-hot-plug drive.
6.
Remove the drive from the carrier.
To replace the component, reverse the removal procedure.
Hot-plug drive blanks
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1.
If installed, remove the security bezel ("
Remove the security bezel (optional)
" on page
27
).
2.
Remove the drive blank.