Monitoring and Analyzing Switch Operation
Port and Static Trunk Monitoring Features
CLI: Configuring Port and Static Trunk Monitoring
Port and Static Trunk Monitoring Commands Used in This Section
show monitor
below
mirror-port
page B-26
monitor
page B-27
You must use the following configuration sequence to configure port and static
trunk monitoring in the CLI:
1. Assign a monitoring (mirror) port.
2. Designate the port(s) and static trunk(s) to monitor.
Displaying the Monitoring Configuration.
This command lists the port
assigned to receive monitored traffic and the ports and/or trunks being
monitored.
Syntax
:
show monitor
For example, if you assign port A6 as the monitoring port and configure the
switch to monitor ports A1 - A3,
show monitor
displays the following:
Port receiving monitored traffic.
Monitored Ports
Figure B-21. Example of Monitored Port Listing
Configuring the Monitor Port.
This command assigns or removes a mon
itoring port, and must be executed from the global configuration level. Remov
ing the monitor port disables port monitoring and resets the monitoring
parameters to their factory-default settings.
Syntax
:
[no] mirror-port [<
port-num
>]
For example, to assign port A6 as the monitoring port:
HPswitch(config)# mirror-port a6
B-26
Summary of Contents for ProCurve 6108
Page 2: ......
Page 18: ... This page is intentionally blank xvi ...
Page 50: ...Using the Menu Interface Where To Go From Here This page is intentionally unused 3 16 ...
Page 300: ...Port Based Virtual LANs VLANs and GVRP GVRP This page is intentionally unused 12 48 ...
Page 432: ...IP Routing Features Configuring DHCP Relay This page is intentionally unused 16 24 ...
Page 522: ...Troubleshooting Restoring a Flash Image This page is intentionally unused C 44 ...
Page 528: ...MAC Address Management Determining MAC Addresses This page is intentionally unused D 6 ...
Page 532: ...Daylight Savings Time on HP ProCurve Switches This page is intentionally unused E 4 ...
Page 546: ... This page is intentionally unused 14 Index ...