HP StorageWorks Modular Smart Array 30 User Guide
D-1
HP CONFIDENTIAL
Writer: Susan Caesar File Name: h-appd SCSI address map.doc
Codename: NorthStar Part Number: 335900-002 Last Saved On: 10/2/03 4:01 PM
D
SCSI Address Map
The I/O module assigns a SCSI ID (address) to each drive bay in the system.
IMPORTANT: Not all controllers support the listed SCSI IDs. For more information about the
SCSI IDs that a particular controller supports, refer to the controller documentation. If the
controller does not support a particular SCSI ID, install only a drive blank in the corresponding
bay. Installing a disk drive in this case causes an address conflict.
Table D-1: SCSI ID Maps
Bay Number
SCSI ID
Formula
Single-Port Module
1-6
0-5
[bay number] – 1
7-14
8-15
[bay number] + 1
Dual-Port Module
1-6
Bus A, ID 0-5
[bay number] – 1
7
Bus A, ID 8
8-13
Bus B, ID 0-5
[bay number] – 8
14
Bus B, ID 8
Note: SCSI IDs 6 and 7 are reserved for controller use.
Summary of Contents for MSA 30
Page 6: ......