Installing the System in a Rack
2-2
HP StorageWorks Modular Smart Array 30 User Guide
HP CONFIDENTIAL
Writer: Susan Caesar File Name: c-ch2 Installing the System in a Rack.doc
Codename: NorthStar Part Number: 335900-002 Last Saved On: 10/2/03 3:49 PM
Power Supply Assembly
Grasp the power supply assembly by the blower unit, lift and hold the purple release
latch, and pull the assembly out of the system.
EMU
Grasp the purple handle on the EMU, and pull the EMU out of the system.
I/O Module
Grasp the handle, press and hold the purple release latch, and pull the module out of
the system.
Mounting the System in a Rack
11 kg (24 lb) empty
31 kg (68 lb) full
WARNING: Use at least two people to move or install a system. For
greater safety and easier installation, reduce the system weight by
removing the disk drives, power supply units, blowers, EMU, and
I/O module. This procedure reduces the system weight to
approximately 11 kg (24 lb). Although a single person can lift this
amount, the empty system is still awkward to install because of its
physical size.
IMPORTANT: The following procedure describes installation in a square-hole rack. For
information about installing the system in a round-hole rack, refer to the rack documentation.
Each disk system requires a vertical rack space of 3U (equivalent to 133 mm, or 5.25
in.).
WARNING: The weight of a system when full exceeds 31 kg (68 lb). Install the
system in the lowest available position in the rack.
1.
Using the rack template in the system kit as a guide, make pencil marks on the
rack to indicate where the rails for the system are to be located.